KSTAR YDC9110S — Specifications
| Capacity | 10KVA |
| Model | KSTAR YDC9110S |
KSTAR YDC9110S — Main Input Specifications
| Rated Input Voltage | 220Vac |
| Input Voltage Range | 120Vac~276Vac |
| Number of Phases | Single Phase, Three Wires |
| Input Frequency Range | 50Hz: 45~55; 60Hz: 54~66 (50/60 Auto-adaptive) |
| Input Power Factor | ≥0.99 |
KSTAR YDC9110S — Bypass Input Specifications
| Rated Input Voltage | 220/230/240 |
| Input Voltage Range | 220 Upper Limit: ±25% (Optional +10%, 15%, 20%); 230 Upper Limit: +20% (Optional +10%, 15%); 240 Upper Limit: +15% (Optional +10%); Lower Limit: -45% (Optional -20%, -30%) |
| Number of Phases | Single Phase, Three Wires |
| Bypass Synchronization Range | ±10% |
KSTAR YDC9110S — Output Specifications
| Voltage (Vac) | 220/230/240±1% |
| Frequency | Utility Mode: Synchronized with Input; When Utility Frequency Exceeds ±10% (Configurable: ±1%, ±2%, ±4%, ±5%), Output Frequency Is 50/60 (±0.1); Battery Mode: 50/60 (±0.1) |
| Waveform | Sine Wave, THDV≤2% (100% Linear Load) |
| Transfer Time (ms) | Utility Power ↔ Battery: 0; Utility Power ↔ Bypass: 0 (Synchronized) |
| Overall Efficiency | ≥92% |
| Overload Capability | ≤110%, 60min; ≤125%, 10min; ≤150%, 1min; >150%: Immediate Transfer to Bypass |
| Power Factor | 0.8 (0.9 Optional) |
KSTAR YDC9110S — Batteries
| Battery Voltage | ±96; ±108; ±120 (16/18/20 Batteries Optional) |
KSTAR YDC9110S — Environment
| Operating Temperature (℃) | 0~40 |
| Storage Temperature (℃) | -25~55 (Excluding Batteries) |
| Relative Humidity | 0~95% (Non-condensing) |
| Operating Altitude | <1500m; Above 1500m, Derate in Accordance with GB/T3859.2 |
| Noise (dB) | ≤55 |
KSTAR YDC9110S — Other Features
| Alarm Functions | Alarms for Overload, Utility Power Abnormality, UPS Faults, Battery Undervoltage and Other Conditions |
| Protection Functions | Alarms for Short Circuit, Overload, Overtemperature, Battery Undervoltage, Overvoltage/Undervoltage and Fan Faults |
| Communication Functions | RS232 or USB; Optional SNMP Card, Relay Card and Parallel-operation Card |
KSTAR YDC9110S — Mechanical Specifications
| Dimensions (W*D*H), mm | 250*502*616 (Including Casters) / 220*481*438 |
| Net Weight (kg) | 64 |
| Applicable Standard | YD/T 1095-2008 |
KSTAR YDC9110S — Warranty
| Standard Warranty | Repair or Replacement within 1 Year |